Case Summary: SDN VM 网络适配器策略推送失败 — Firewall Service 主副本异常

Product/Service: Azure Stack HCI / Windows Server SDN (Software Defined Networking)


1. 症状 (Symptoms)

  • 客户通过 WAC (Windows Admin Center) 设置 VM 网络适配器的虚拟网络时失败,UI 报错:“couldn’t save the network settings”
  • VM 无法获取虚拟 IP 地址
  • 该错误为纯 SDN 策略推送问题,与 WAC UI 本身无关

2. 背景 (Background / Environment)

  • 平台:Azure Stack HCI,运行 SDN (Software Defined Networking) 环境
  • 组件
    • Network Controller (NC) 集群:多节点部署
    • Hyper-V Host:运行目标 VM
    • 涉及的 SDN 微服务:SDNAPI、SDNVSM (Virtual Switch Manager)、SDNFW (Firewall Service)
  • 关键网络连接(Host ↔ NC)
    • NCHA → SDNAPI:6640:Host Agent 向 NC 发送端口添加/移除通知
    • SDNVSM/SDNFW → NCHA:6640:NC 向 Host 推送 VNET 策略和防火墙策略
    • NC (SDNFW/SDNVSM) → NCHA:443:WCF 连接,用于推送 DHCP、DNS、PA 配置等策略
  • VMsdn-vnet-vm01,MAC 地址 00-1D-D8-AA-1C-34

3. Troubleshooting 过程 (Investigation & Troubleshooting)

Step 1:确认网络适配器的真实配置状态

做了什么:通过 Network Controller REST API 导出网络接口 JSON 获取配置状态。

Get-NetworkControllerNetworkInterface -ConnectionUri $uri | ConvertTo-Json -Depth 10 > C:\networkinterface.txt

通过 VM 的 MAC 地址定位正确的接口:

Get-VMNetworkAdapter -VMName sdn-vnet-vm01

发现了什么:从 JSON 文件中获取了 3 条关键信息:

信息项 含义
Instance ID d072ad2b-ff97-4823-a84f-8dd75c138590 后续 ETL 日志分析的关键标识
Provisioning State Succeeded NC 成功创建了策略
Configuration State Failure 策略推送到 Host 失败

错误详情:

{
  "configurationState": {
    "status": "Failure",
    "detailedInfo": [{
      "source": "VirtualSwitch",
      "message": "The host has not yet established communication with the Network Controller.",
      "code": "HostNotConnectedToController"
    }]
  }
}

得出的结论

  • Provisioning 成功 + Configuration 失败 = 策略在 NC 端已创建成功,但推送到 Host 的过程失败
  • 错误消息 HostNotConnectedToController 指向 Host 与 NC 之间的网络连接问题

Step 2:检查 Host 与 NC 之间的 6640/443 连接

做了什么

  • 通过 Get-NetworkControllerReplica 确认各微服务所在的 NC 节点
  • 使用 netstat -abno 逐一检查所有关键连接

发现了什么

连接 状态
NCHA → SDNAPI:6640 ✅ 正常
SDNVSM → NCHA:6640 ✅ 正常
SDNFW → NCHA:6640 ✅ 正常
SDNVSM → NCHA:443 ✅ 正常
SDNFW → NCHA:443 ❌ 未建立

得出的结论:SDNFW 到 NCHA 的 443 TLS 连接未建立,这是策略推送失败的直接原因。

Step 3:排查 443 连接失败原因

做了什么:按常规 TLS 连接问题排查三要素检查:

  1. TCP 443 端口连通性 → ✅ 正常
  2. SDNFW 服务健康状态:
    Get-ServiceFabricServiceHealth -ServiceName fabric:/NetworkController/FirewallService
    # AggregatedHealthState: Ok
    

    → ✅ 正常

  3. 证书/信任链 → ✅ 正常

得出的结论:三项基础检查均正常,需要进一步从 VM 端口状态和 NC ETL 日志深入分析。

Step 4:检查 VM 网络接口的端口状态

做了什么:先获取端口信息再查询端口状态。

# 获取 VM 网络适配器的 Port Profile
Get-SDNVmNetworkAdapterPortProfile -AllVMs

发现了什么:ProfileId 为空(全零 GUID),表示端口配置未被正确应用:

VMName      : sdn-vnet-vm01
MacAddress  : 001DD8AA1C34
ProfileId   : {00000000-0000-0000-0000-000000000000}   ← 空!
ProfileData : 2
PortId      : D267D29E-9E28-4546-BAF9-016437966ADC

检查端口状态:

vfpctrl.exe /port D267D29E-9E28-4546-BAF9-016437966ADC /get-port-state
# PORT STATE
#   Enabled : FALSE
#   Blocked : TRUE    ← 端口被阻塞!

得出的结论:VM 网络端口被 VFP 阻塞(Blocked: TRUE),且 ProfileId 为空,说明 SDNFW 未成功将防火墙策略推送到 Host,导致端口保持默认阻塞状态。

补充:尝试手动设置 ProfileId 到已知的 Instance ID:

Set-SdnVMNetworkAdapterPortProfile -VMName "sdn-vnet-vm01" -MACAddress 001DD8AA1C34 -ProfileID "d072ad2b-ff97-4823-a84f-8dd75c138590"

在其他类似 case 中此方法可以临时解决问题,但在本案例中未能立即生效。

Step 5:分析 SDNFW NC ETL 日志

做了什么:从 SDNFW 所在的 NC 节点收集 ETL 日志(路径:C:\Windows\tracing\SDNDiagnostics\Logs)。

发现了什么:日志中出现两个关键错误:

错误 1 — WCF 通信对象已被中止

ControllerTransientException: An internal error occurred in a WCF operation
---> System.ServiceModel.CommunicationObjectAbortedException:
The communication object, System.ServiceModel.Channels.ClientReliableDuplexSessionChannel,
cannot be used for communication because it has been Aborted.

错误 2 — Service Fabric 主副本异常

Primary recovery task failed: System.AggregateException
---> ImosException: Network Controller operation failed
---> System.Fabric.FabricNotPrimaryException:
Must be primary to begin read/write session

得出的结论:SDNFW 服务的主副本(Primary Replica)虽然报告健康状态为 OK,但实际上出现了内部异常,WCF 通信通道被中止,导致无法与 Host Agent 建立 443 连接推送防火墙策略。

Step 6:迁移 Firewall Service 主副本

做了什么:将 SDNFW 主副本迁移到另一个 NC 节点:

Move-ServiceFabricPrimaryReplica -ServiceName fabric:/NetworkController/FirewallService -NodeName NC03

结果:问题解决。

Step 7:验证修复

做了什么:全面验证所有指标。

验证结果

检查项 结果
VM 获取虚拟 IP ✅ 成功
NCHA → SDNAPI:6640 ✅ 正常
SDNVSM/SDNFW → NCHA:6640 ✅ 正常
SDNVSM → NCHA:443 ✅ 正常
SDNFW → NCHA:443 ✅ 正常
Configuration State ✅ Success
Provisioning State ✅ Succeeded
VM 端口状态 ✅ Allowed

4. Blockers 与解决 (Blockers & How They Were Resolved)

Blocker 影响 如何解决
SDNFW 服务健康状态报告 OK,但实际通信异常 常规健康检查无法发现问题,排查方向一度受阻 结合端口状态检查(VFP blocked)和 ETL 日志中的 FabricNotPrimaryException 错误定位根因
隐藏记录不可见 ProfileId 为空不直观反映根因 通过理解 SDN 策略推送完整链路(SDNAPI → SDNVSM → SDNFW → NCHA → VFP),层层排查定位到 SDNFW 环节
手动设置 ProfileId 的临时方案未生效 无法快速恢复业务 需要从根本上修复 SDNFW 服务,而非仅修补端口配置

5. 根因与解决方案 (Root Cause & Resolution)

Root Cause

SDNFW (Network Controller Firewall Service) 的 Service Fabric 主副本出现内部异常FabricNotPrimaryException),导致:

  1. SDNFW 无法正常执行读写会话(Primary Recovery 任务失败)
  2. SDNFW 与 NCHA 之间的 WCF 443 通信通道被中止(CommunicationObjectAbortedException
  3. 防火墙策略无法推送到 Hyper-V Host
  4. VM 网络适配器的 VFP 端口保持默认阻塞状态(Blocked: TRUE,ProfileId 为空)
  5. VM 无法获取虚拟 IP 地址

整个策略推送链路:SDNAPI → SDNVSM → SDNFW → NCHA:443 → VFP Port,在 SDNFW → NCHA:443 环节断裂。

Resolution

将 SDNFW 主副本迁移到健康的 NC 节点:

Move-ServiceFabricPrimaryReplica -ServiceName fabric:/NetworkController/FirewallService -NodeName NC03

迁移后,SDNFW 在新节点上正常初始化主副本,WCF 通道重新建立,策略成功推送到 Host。

Workaround

在某些类似场景中,手动设置 VM 网络适配器的 ProfileId 可以临时恢复连通性:

Set-SdnVMNetworkAdapterPortProfile -VMName "<VMName>" -MACAddress <MAC> -ProfileID "<InstanceID>"

但此方法仅为临时方案,不能替代修复 SDNFW 服务本身。

6. 经验教训 (Lessons Learned)

技术知识

  • SDN 策略推送链路SDNAPI → SDNVSM → SDNFW → NCHA → VFP。理解完整链路是排查 SDN 问题的基础
  • Host ↔ NC 三大关键连接
    • NCHA → SDNAPI:6640(端口通知)
    • SDNVSM/SDNFW → NCHA:6640(VNET/FW 策略推送)
    • SDNFW/SDNVSM → NCHA:443(WCF,推送 DHCP/DNS/PA 等)
  • Provisioning vs Configuration State
    • Provisioning = NC 端策略创建状态
    • Configuration = 策略推送到 Host 的状态
    • Provisioning 成功 + Configuration 失败 = 推送链路问题
  • ProfileId 为空 + VFP Port Blocked = 防火墙策略未到达 Host 的典型症状
  • Service Fabric 健康状态可能”欺骗性”报告 OK,实际服务内部可能存在副本异常

排查方法

  1. 从 networkinterface.json 入手:通过 MAC 地址定位接口,检查 Provisioning 和 Configuration State
  2. 逐一验证 Host ↔ NC 的所有关键端口:使用 Get-NetworkControllerReplica 确认微服务节点,netstat -abno 检查连接
  3. 检查 VFP 端口状态vfpctrl.exe /port <PortId> /get-port-state 是判断端口是否被防火墙策略阻塞的直接方法
  4. NC ETL 日志是深度诊断的关键:位于 C:\Windows\tracing\SDNDiagnostics\Logs,需根据微服务位置从对应的 NC 节点收集
  5. 对比正常 vs 异常场景:建立正常场景的基线(ProfileId 非空、Port State Enabled、Configuration Success),有助于快速定位偏差

关键命令速查

# 导出网络接口配置
Get-NetworkControllerNetworkInterface -ConnectionUri $uri | ConvertTo-Json -Depth 10

# 查看 VM 网络适配器
Get-VMNetworkAdapter -VMName <VMName>

# 查看端口 Profile
Get-SDNVmNetworkAdapterPortProfile -AllVMs

# 查看 VFP 端口状态
vfpctrl.exe /port <PortId> /get-port-state

# 查看 NC 微服务副本分布
Get-NetworkControllerReplica

# 检查 Service Fabric 服务健康
Get-ServiceFabricServiceHealth -ServiceName fabric:/NetworkController/FirewallService

# 迁移主副本
Move-ServiceFabricPrimaryReplica -ServiceName fabric:/NetworkController/FirewallService -NodeName <NodeName>

# 手动设置 Port Profile(临时方案)
Set-SdnVMNetworkAdapterPortProfile -VMName <VMName> -MACAddress <MAC> -ProfileID "<InstanceID>"

7. 参考文档 (References)


Case Summary: SDN VM Network Adapter Policy Push Failure — Firewall Service Primary Replica Exception

Product/Service: Azure Stack HCI / Windows Server SDN (Software Defined Networking)


1. Symptoms

  • Customer failed to set VM network adapter to virtual network via WAC (Windows Admin Center). The UI reported: “couldn’t save the network settings”
  • VM could not obtain a virtual IP address
  • This was a pure SDN policy push issue, unrelated to the WAC UI itself

2. Background / Environment

  • Platform: Azure Stack HCI with SDN (Software Defined Networking)
  • Components:
    • Network Controller (NC) cluster: multi-node deployment
    • Hyper-V Host: running the target VM
    • SDN microservices involved: SDNAPI, SDNVSM (Virtual Switch Manager), SDNFW (Firewall Service)
  • Critical network connections (Host ↔ NC):
    • NCHA → SDNAPI:6640: Host Agent sends port add/remove notifications to NC
    • SDNVSM/SDNFW → NCHA:6640: NC pushes VNET and firewall policies to Host
    • NC (SDNFW/SDNVSM) → NCHA:443: WCF connection for pushing DHCP, DNS, PA configurations
  • VM: sdn-vnet-vm01, MAC address 00-1D-D8-AA-1C-34

3. Investigation & Troubleshooting

Step 1: Verify the actual configuration state of the network adapter

Action: Exported network interface JSON from Network Controller REST API.

Get-NetworkControllerNetworkInterface -ConnectionUri $uri | ConvertTo-Json -Depth 10 > C:\networkinterface.txt

Located the correct interface by VM’s MAC address:

Get-VMNetworkAdapter -VMName sdn-vnet-vm01

Finding: Three critical pieces of information from the JSON:

Item Value Meaning
Instance ID d072ad2b-ff97-4823-a84f-8dd75c138590 Key identifier for ETL log analysis
Provisioning State Succeeded NC successfully created the policy
Configuration State Failure Policy push to Host failed

Error details:

{
  "configurationState": {
    "status": "Failure",
    "detailedInfo": [{
      "source": "VirtualSwitch",
      "message": "The host has not yet established communication with the Network Controller.",
      "code": "HostNotConnectedToController"
    }]
  }
}

Conclusion:

  • Provisioning Succeeded + Configuration Failure = Policy was created on NC side, but the push to Host failed
  • Error message HostNotConnectedToController points to network connectivity between Host and NC

Step 2: Check 6640/443 connections between Host and NC

Action:

  • Used Get-NetworkControllerReplica to identify which NC node hosts each microservice
  • Used netstat -abno to check each connection

Finding:

Connection Status
NCHA → SDNAPI:6640 ✅ OK
SDNVSM → NCHA:6640 ✅ OK
SDNFW → NCHA:6640 ✅ OK
SDNVSM → NCHA:443 ✅ OK
SDNFW → NCHA:443 ❌ Not established

Conclusion: The 443 TLS connection from SDNFW to NCHA was not established — this is the direct cause of the policy push failure.

Step 3: Investigate 443 connection failure

Action: Followed standard TLS connection troubleshooting:

  1. TCP 443 port connectivity → ✅ OK
  2. SDNFW service health:
    Get-ServiceFabricServiceHealth -ServiceName fabric:/NetworkController/FirewallService
    # AggregatedHealthState: Ok
    

    → ✅ OK

  3. Certificate/trust chain → ✅ OK

Conclusion: All three baseline checks passed. Deeper investigation via VM port state and NC ETL logs was needed.

Step 4: Check VM network interface port state

Action: Retrieved port profile and port state.

Get-SDNVmNetworkAdapterPortProfile -AllVMs

Finding: ProfileId was empty (all-zero GUID), indicating the port configuration was never applied:

VMName      : sdn-vnet-vm01
MacAddress  : 001DD8AA1C34
ProfileId   : {00000000-0000-0000-0000-000000000000}   ← Empty!
ProfileData : 2
PortId      : D267D29E-9E28-4546-BAF9-016437966ADC

Port state check:

vfpctrl.exe /port D267D29E-9E28-4546-BAF9-016437966ADC /get-port-state
# PORT STATE
#   Enabled : FALSE
#   Blocked : TRUE    ← Port is blocked!

Conclusion: The VM network port was blocked by VFP (Blocked: TRUE) and ProfileId was empty, confirming SDNFW never successfully pushed firewall policies to the Host.

Note: Attempted to manually set ProfileId to the known Instance ID:

Set-SdnVMNetworkAdapterPortProfile -VMName "sdn-vnet-vm01" -MACAddress 001DD8AA1C34 -ProfileID "d072ad2b-ff97-4823-a84f-8dd75c138590"

This approach worked in a different similar case but did not take effect immediately in this scenario.

Step 5: Analyze SDNFW NC ETL logs

Action: Collected ETL logs from the NC node hosting SDNFW (path: C:\Windows\tracing\SDNDiagnostics\Logs).

Finding: Two critical errors in the logs:

Error 1 — WCF communication object aborted:

ControllerTransientException: An internal error occurred in a WCF operation
---> System.ServiceModel.CommunicationObjectAbortedException:
The communication object, System.ServiceModel.Channels.ClientReliableDuplexSessionChannel,
cannot be used for communication because it has been Aborted.

Error 2 — Service Fabric primary replica exception:

Primary recovery task failed: System.AggregateException
---> ImosException: Network Controller operation failed
---> System.Fabric.FabricNotPrimaryException:
Must be primary to begin read/write session

Conclusion: The SDNFW primary replica had an internal exception (FabricNotPrimaryException). Despite reporting healthy status, the WCF communication channel was aborted, preventing the 443 connection to NCHA for policy push.

Step 6: Move Firewall Service primary replica

Action: Moved the SDNFW primary replica to a different NC node:

Move-ServiceFabricPrimaryReplica -ServiceName fabric:/NetworkController/FirewallService -NodeName NC03

Result: Issue resolved immediately.

Step 7: Verification

All indicators confirmed healthy:

Check Result
VM obtained virtual IP ✅ Success
NCHA → SDNAPI:6640 ✅ OK
SDNVSM/SDNFW → NCHA:6640 ✅ OK
SDNVSM → NCHA:443 ✅ OK
SDNFW → NCHA:443 ✅ OK
Configuration State ✅ Success
Provisioning State ✅ Succeeded
VM port state ✅ Allowed

4. Blockers & How They Were Resolved

Blocker Impact Resolution
SDNFW health reported OK despite internal communication failure Standard health checks couldn’t surface the problem, misdirected investigation Combined VFP port state check (blocked) with ETL log analysis revealing FabricNotPrimaryException
Empty ProfileId didn’t directly indicate root cause Not intuitive to trace back to SDNFW issue Understood the full SDN policy push chain (SDNAPI → SDNVSM → SDNFW → NCHA → VFP) and traced layer by layer
Manual ProfileId workaround didn’t take effect Couldn’t quickly restore service Required fixing the SDNFW service itself rather than patching the port configuration

5. Root Cause & Resolution

Root Cause

The SDNFW (Network Controller Firewall Service) Service Fabric primary replica experienced an internal exception (FabricNotPrimaryException), causing:

  1. SDNFW could not perform read/write sessions (Primary Recovery task failed)
  2. WCF 443 communication channel between SDNFW and NCHA was aborted (CommunicationObjectAbortedException)
  3. Firewall policies could not be pushed to the Hyper-V Host
  4. VM network adapter VFP port remained in default blocked state (Blocked: TRUE, ProfileId empty)
  5. VM could not obtain a virtual IP address

The full policy push chain: SDNAPI → SDNVSM → SDNFW → NCHA:443 → VFP Port was broken at the SDNFW → NCHA:443 segment.

Resolution

Move the SDNFW primary replica to a healthy NC node:

Move-ServiceFabricPrimaryReplica -ServiceName fabric:/NetworkController/FirewallService -NodeName NC03

After migration, SDNFW properly initialized the primary replica on the new node, the WCF channel was re-established, and policies were successfully pushed to the Host.

Workaround

In some similar scenarios, manually setting the VM network adapter’s ProfileId can temporarily restore connectivity:

Set-SdnVMNetworkAdapterPortProfile -VMName "<VMName>" -MACAddress <MAC> -ProfileID "<InstanceID>"

This is a temporary fix only and does not substitute for repairing the SDNFW service itself.

6. Lessons Learned

Technical Knowledge

  • SDN policy push chain: SDNAPI → SDNVSM → SDNFW → NCHA → VFP. Understanding the full chain is foundational for SDN troubleshooting
  • Three critical Host ↔ NC connections:
    • NCHA → SDNAPI:6640 (port notifications)
    • SDNVSM/SDNFW → NCHA:6640 (VNET/FW policy push)
    • SDNFW/SDNVSM → NCHA:443 (WCF for DHCP/DNS/PA)
  • Provisioning vs Configuration State:
    • Provisioning = policy creation status on NC side
    • Configuration = policy push status to Host
    • Provisioning Succeeded + Configuration Failed = push chain problem
  • Empty ProfileId + VFP Port Blocked = classic symptom that firewall policies haven’t reached the Host
  • Service Fabric health status can be misleading — the service may report OK while the primary replica has internal exceptions

Troubleshooting Methodology

  1. Start with networkinterface.json: Locate the interface by MAC address, check Provisioning and Configuration State
  2. Verify all critical Host ↔ NC ports: Use Get-NetworkControllerReplica to identify microservice nodes, netstat -abno to check connections
  3. Check VFP port state: vfpctrl.exe /port <PortId> /get-port-state directly shows whether the port is blocked by firewall policies
  4. NC ETL logs are key for deep diagnosis: Located at C:\Windows\tracing\SDNDiagnostics\Logs, collect from the correct NC node based on microservice placement
  5. Compare working vs non-working scenarios: Establish a baseline of normal behavior (non-empty ProfileId, Port State Enabled, Configuration Success) to quickly identify deviations

Key Command Reference

# Export network interface configuration
Get-NetworkControllerNetworkInterface -ConnectionUri $uri | ConvertTo-Json -Depth 10

# View VM network adapter
Get-VMNetworkAdapter -VMName <VMName>

# View port profile
Get-SDNVmNetworkAdapterPortProfile -AllVMs

# Check VFP port state
vfpctrl.exe /port <PortId> /get-port-state

# View NC microservice replica distribution
Get-NetworkControllerReplica

# Check Service Fabric service health
Get-ServiceFabricServiceHealth -ServiceName fabric:/NetworkController/FirewallService

# Move primary replica
Move-ServiceFabricPrimaryReplica -ServiceName fabric:/NetworkController/FirewallService -NodeName <NodeName>

# Manually set port profile (temporary workaround)
Set-SdnVMNetworkAdapterPortProfile -VMName <VMName> -MACAddress <MAC> -ProfileID "<InstanceID>"